- (01-45) -
MULTI TYPE
2, 3, 4 ROOMS TYPE
MULTI TYPE
2, 3, 4 ROOMS TYPE
Model name AS
G07LMCA AS
G09LMCA AS
G12LMCA AS
G14LMCA
Power source 1ø 230V ~ 50Hz
Available voltage range 198-264V
Capacity 2.0kW Class 2.5kW Class 3.5kW Class 4.0kW Class
Input power W 15 17 22 28
Running current A 0.13 0.15 0.19 0.25
Fan
Airow
rate
Cooling
High
m
3
/h
560 600 660 730
Med 500 520 560 600
Low 430 430 450 530
Quiet 310 310 310 360
Heating
High 560 600 660 730
Med 500 520 560 615
Low 430 430 470 560
Quiet 330 330 330 375
Type × Q’ty Crossow × 1
Motor output W 30
Sound pressure level *
Cooling
High
dB (A)
36 37 40 42
Med 32 33 36 38
Low 29 29 30 33
Quiet 21 21 21 25
Heating
High 36 37 40 42
Med 32 33 36 38
Low 29 29 31 35
Quiet 22 22 22 27
Sound power level
Cooling 51 52
54 56
Heating 51 52 55 57
Heat
exchanger
Dimensions
(H × W × D)
mm
Main: 320 × 630 × 20
Sub: 84 × 630 × 13.3
Fin pitch Main: 1.1, Sub: 1.4
Rows × Stages Main: 2 × 20, Sub: 1 × 4
Pipe type Copper tube
Fin type Aluminium
Enclosure
Material Polystyrene
Colour
WHITE
(Approximate colour of MUNSELL N9.25)
Dimensions
(H × W × D)
Net
mm
268 × 840 × 203
Gross 270 × 884 × 336
Weight
Net
kg
8.5
Gross 10.5
Connection
pipe
Size
Liquid
mm
Φ6.35 (Φ1/4in)
Gas Φ9.52 (Φ3/8in) Φ12.7 (Φ1/2in)
Method Flare
Drain hose
Material PP+LLDPE
Size mm Φ13.8 (I.D.), Φ15.8 to 16.7 (O.D.)
Operation range
Cooling
°C 18 to 32
%RH 80 or less
Heating °C 16 to 30
Remote controller type Wireless [Wired (option)]
NOTE:
The protective function may work when using it outside the operation range.
*: These are the measured values in the manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than
the specied values here.