EasyManua.ls Logo

Fujitsu ABUH18LUAS - E: 58.↓. Intake Grille Error (Indoor Unit)

Fujitsu ABUH18LUAS
226 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-16. E: 58.X. Intake grille error (Indoor unit)
Indicator
→ired remote
controller
Error code E: 58
Detective actuator
Indoor unit main PCB
→hen the Micro switch is detected open while running
the compressor.
Micro switch
Forecast of cause
Micro switch failure
Shorted connector/wire
Main PCB failure
Check point 1. Check limit switch
Check operation of Micro switch. (any blocking by dust, etc.)
Remove Micro switch and check ON/OFF switching operation by using a meter.
-> If micro switch is detective, replace it.
Check point 2. Check connector (CN11)/wire
Check loose contact of CN11/shorted wire (pinched wire).
-> Replace micro switch if the wire is abnormal
Check point 3. Replace the main PCB
If Check Point 1 and 2 do not improve the symptom, replace the main PCB.
End
2-16. E: 58.↓. Intake grille error (Indoor unit) - (03-22) - 2. Troubleshooting with error code
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents