En-15
Unit number
Error code
Ex.Self-diagnosis
SU
MO
TU
WE
TH FR
SA
Error code Error contents
01
13
26
27
Indoor signal error
00 Wired remote controller abnormal
02 Indoor room temperature sensor error
04
Indoorheatexchangertemperaturesensor
(middle) error
28
Indoorheatexchangertemperaturesensor(inlet)
error
09 Float switch operated
0c Outdoor discharge pipe temperature sensor error
06
Outdoorheatexchangertemperaturesensor
(outlet) error
0A Outdoor temperature sensor error
0E Heat sink thermistor (Inverter) error
15 Compressor temperature sensor error
1d 2-way valve temperature sensor error
1E 3-way valve temperature sensor error
29
Outdoorheatexchangertemperaturesensor
(middle) error
2d Heat sink thermistor (P.F.C) error
20 Indoor manual auto switch abnormal
2A Power supply frequency detection error
17 IPM protection
18 CT error
1A Compressor location error
1b Outdoor fan error
1F Connected indoor unit abnormal
1c Outdoor unit computer communication error
2E Inverter error
12 Indoor fan abnormal
0F Discharge temperature error
24 Excessivehighpressureprotectiononcooling
2c 4-way valve abnormal
16
Pressure switch abnormal, Pressure sensor abnormal
2b Compressor temperature error
2F Low pressure error
19 Activelterabnormal
25 PFC circuit error
30 Refrigerant circuit address set-up error
31 Master unit, Slave unit set-up error
32 Connected the indoor number set-up error
33 P.F.C. printed circuit board error
If “C0” appears in the unit number display, there is a remote
controller error.
Unit number Error code Content
C0 1d
Incompatible indoor unit is
connected
C0 1c
Indoorunit↔remotecontrol-
ler communication error
13. SPECIAL INSTALLATION METHODS
CAUTION
When setting DIP switches, do not touch any other parts •
on the circuit board directly with your bare hands.
Be sure to turn off the main power.•
[Group control system]
A number of indoor units can be operated at the same time
using a single remote controller.
Wiring method (indoor unit to remote controller) (1)
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
Indoor unit
0
In
doo
r
u
nit 1In
doo
r
u
nit 2 Indoor unit
3
B
us
wir
e
R
e
m
o
t
e
co
ntr
o
ll
e
r
co
r
d
When
g
round wire is necessar
y
R
e
m
o
t
e
co
ntr
o
ll
er
DIP switch setting (Indoor unit) (2)
Set the unit number of each indoor unit using the DIP
switches on the indoor unit circuit board. (See the follow-
ingtableandgure.)
The DIP switches are normally set to make the unit
number 0.
Indoor unit
Unit number
DIP SWITCH No.
1 2 3 4
0 OFF OFF OFF OFF
1 ON OFF OFF OFF
2 OFF ON OFF OFF
3 ON ON OFF OFF
4 OFF OFF ON OFF
5 ON OFF ON OFF
6 OFF ON ON OFF
7 ON ON ON OFF
8 OFF OFF OFF ON
9 ON OFF OFF ON
10 OFF ON OFF ON
11 ON ON OFF ON
12 OFF OFF ON ON
13 ON OFF ON ON
14 OFF ON ON ON
15 ON ON ON ON
Example : No. 3
ON
1234
NOTE
Be sure to set the unit numbers sequentially.
1125-9379122009.indd 15 2008/11/26 7:57:06
www.enindel.com