TROUBLESHOOTING
Symptom
Doesn’t operate at all:
Poor Cooling (or Heating)
performance:
The unit operates differently
from the Remote Controllers
setting:
See Page
8 - 9
6
5
CHECK ONCE
MORE
Items to check
Has the circuit breaker been turn off?
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the timer operating?
Is the Air Filter dirty?
Are the air conditioners intake grille or outlet port blocked?
Did you adjust the room temperature settings (thermostat) correctly?
Is there a window or door open?
In the case of Cooling operation, is a window allowing bright sunlight
to enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?
Is the unit set for SUPER QUIET operation?
Are the Remote Controllers batteries dead?
Are the Remote Controllers batteries loaded properly?
OPERATING TIPS
If the problem persists after performing these checks, or if you notice burning smells, or the OPERATION Indicator Lamp (Fig. 3
5
)
and the TIMER Indicator Lamp (Fig. 3
6
) ashes, and ECONOMY Indicator Lamp(Fig.3
7
) ashes fast. immediately stop operation,
turn off the electrical breaker and consult authorized service personnel.
Operation and Performance
Heating Performance
This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
to indoor unit. As a result, the operating performance is
reduced as outdoor air temperature drops. If you feel that
insufficient heating performance is being produced, we
recommend you use this air conditioner in conjunction with
another kind of heating appliance.
Heat-pump air conditioners heat your entire room by recir-
culating air throughout the room, with the result that some
time may be required after rst starting the air conditioner
until the room is heated.
Microcomputer-controlled Automatic Defrosting
When using the Heating mode under conditions of low out-
door temperature and high humidity, frost may form on the
outdoor unit, resulting in reduced operating performance.
In order to prevent this kind of reduced performance, this
air conditioner is equipped with a Microcomputer-controlled
Automatic Defrosting function. If frost forms, the air con-
ditioner will temporarily stop, and the defrosting circuit will
operate brie y (for about 7-15 minutes).
During Automatic Defrosting operation, the OPERATION
Indicator Lamp (green) will ash.
After heating operation stops, if frost forms on the outdoor
unit, the unit will start Automatic Defrosting operation. At
this time, the outdoor unit will automatically stop after oper-
ating for a few minutes.
En-17