8-4. Details of function
¢
Control input function
When function setting is "Operation/Stop" mode 1
In the case of "Edge" input
Function
setting /
Rotary SW of
External input and
output PCB
External input Input signal Command
46-00
- Input of indoor unit Terminal
Off → On Operation
On → Off Stop
60-00 / 1
External input and
output PCB
Input 1
Off → On Operation
On → Off Stop
Operation
Stop
Remote controller
On
Off
Indoor unit
On
Input
In the case of "Pulse" input
Function
setting /
Rotary SW of
External input and
output PCB
External input Input signal Command
46-00 60-00 / 1
External input and
output PCB
Input 1 Pulse Operation
Input 2 Pulse Stop
On
On
Off
Operation
Stop
Remote controller
On
Off
Indoor unit
Input 1
Input 2
NOTES:
The last command has priority.
The indoor units within the same remote controller group operates in the same mode.
- 42 -
8-4. Details of function
8. External input and output
CASSETTE TYPE
AUXG24-54KRLB
CASSETTE TYPE
AUXG24-54KRLB

Table of Contents

Other manuals for Fujitsu AOG30KATA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOG30KATA Series and is the answer not in the manual?

Fujitsu AOG30KATA Series Specifications

General IconGeneral
BrandFujitsu
ModelAOG30KATA Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals