At the time when the air conditioner is switched from the Cooling mode to Heating mode,
the compressor is stopped, and the 4-way valve is switched in 3 minutes later after the compressor stopped.
1-13. 4-WAY VALVE EXTENSION SELECT
1-14. AUTO RESTART
01-23
1-15. MANUAL AUTO OPERATION (When using the Wireless RC)
If MANUAL / AUTO Button is pushed for less than 10 seconds,
the operation is controlled as shown in Table 9.
If the remote control is lost or battery power dissipated, this function will work without the remote control.
Operation mode
Auto changeover
Auto
Normal
Normal
Continuous (No timer setting available)
24°C
(Table 9)
Setting temp.
Vertical louver
Horizontal louver
OFF
Economy
OFF
Swing
Fan control mode
Timer mode
When the power was interrupted by a power failure, etc. during operation, the operation contents
at that time are memorized and when power is recovered, operation is automatically resumed with
the memorized operation contents.
(Table 8 : Operation contents memorized when the power is interrupted)
Operation mode
Set temperature
Set air flow
Set air flow direction
Swing
Economy operation
10°C Heat operation
Thermistor detected position
Timer mode
Wireless remote
controller
Wired remote controller
(Memory Backup : Disable)
Wired remote controller
(Memory Backup : Enable)
OFF Timer
ON Timer
WEEKLY Timer
Temperature
: Memorize
: Not memorize
*It is necessary to set on the DIP-SW1-No,6 of the wired remote controller, to enable the memory backup.
Refer to the installation manual of wired remote controller for details.
SET BACK Timer