- 5 -
WALL MOUNTED
ASU30RLE
Supporting operation
When the room temperature does not reach to the set point after a certain period of time, regard-
less of the primary-secondary relation of the unit, operation start indication is issued to another
unit and both indoor units perform air conditioning simultaneously.
NOTE: While performing this function, following functions cannot be used:
Operation modes other than cooling
Airflow modes other than HIGH
Temperature setting other than 76°F (24°C)
POWERFUL mode
MIN. HEAT operation
ECONOMY operation
On/off timer, program timer, and SLEEP timer
Weekly timer on secondary unit
Human sensor function
Shutdown operation
Starting operation on secondary unit
To stop the operation, shutdown the power supply.
On
Indoor unit A
Indoor unit B
Off
On
Off
Set point non-attainment
*: Operaion is started even when the unit is stopped by the weekly timer.
Ts + 1°F (0.5 °C)
Ts + 5°F (2.5 °C)
Supporting operation: On
Supporting operation: Off

Other manuals for Fujitsu AOU30RLXEH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOU30RLXEH and is the answer not in the manual?

Fujitsu AOU30RLXEH Specifications

General IconGeneral
BrandFujitsu
ModelAOU30RLXEH
CategoryAir Conditioner
LanguageEnglish

Related product manuals