4-14. SAFETY DEVICE
OUTDOOR UNIT
INDOOR UNIT
PROTECTION FORM
FAN MOTOR PROTECTION THERMAL PROTECTOR 302±9°F 105±5°C
COMPRESSOR PROTECTION THERMAL PROTECTOR
OFF : 257°F
ON : 176°F
OFF : 125°C
ON : 80°C
HIGH PRESSURE PROTECTION PRESSURE SWITCH
OFF : 609±15 PSI
ON : 464 ±22 PSI
OFF : 4.2±0.1MPa
ON : 3.2±0.15MPa
AOU42R
3.15A 250V
FUSE ON MAIN PCB
CURRENT FUSE
5A 250V
PROTECTION FORM
PCB FUSE CURRENT FUSE
FAN MOTOR PROTECTION THERMAL PROTECTOR 302±9°F 105±5°C