CONTENTS
4. CONTROL AND FUNCTIONS
1. Compressor frequency control..................................................................04-1
1-1. Cooling operation ...........................................................................................................04-1
1-2. Heating operation ...........................................................................................................04-3
1-3. Dry operation..................................................................................................................04-4
1-4. Compressor frequency at normal start-up ......................................................................04-4
1-5. Compressor frequency limitation by outdoor temperature ..............................................04-5
2. Auto changeover operation........................................................................04-7
3. Fan control...................................................................................................04-9
3-1. Indoor fan control............................................................................................................04-9
3-2. Outdoor fan control.......................................................................................................04-13
4. Louver control ...........................................................................................04-16
4-1. Horizontal louver control...............................................................................................04-16
4-2. Vertical louver control ..................................................................................................04-16
4-3. Swing operation............................................................................................................04-17
5. Timer operation control ............................................................................04-18
5-1. Wireless remote control................................................................................................04-18
5-2. Wired remote control ....................................................................................................04-20
6. Defrost operation control .........................................................................04-23
6-1. Defrost operation in heating operation stopped ............................................................04-24
7. Various control..........................................................................................04-25
7-1. Auto restart...................................................................................................................04-25
7-2. MANUAL AUTO operation............................................................................................04-25
7-3. Forced cooling operation ..............................................................................................04-26
7-4. MIN. HEAT operation ...................................................................................................04-26
7-5. ECONOMY operation ...................................................................................................04-26
7-6. POWERFUL operation ................................................................................................04-27
7-7. Compressor preheating ................................................................................................04-27
7-8. Electronic expansion valve control ...............................................................................04-27
7-9. Prevention to restart for 3 minutes (3 minutes st) .........................................................04-28
7-10. 4-way valve control.....................................................................................................04-28
7-11. Outdoor unit low noise operation ................................................................................04-28
8. Various protections...................................................................................04-29
8-1. Discharge gas temperature over-rise prevention control ..............................................04-29
8-2. Anti-freezing control (cooling and dry mode) ................................................................04-29
8-3. Current release control .................................................................................................04-30
8-4. Cooling pressure over-rise protection...........................................................................04-30
8-5. Low outdoor temperature protection.............................................................................04-30
8-6. High temperature and high pressure release control....................................................04-31

Table of Contents

Other manuals for Fujitsu AOUG12LZAH1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOUG12LZAH1 and is the answer not in the manual?

Fujitsu AOUG12LZAH1 Specifications

General IconGeneral
BrandFujitsu
ModelAOUG12LZAH1
CategoryAir Conditioner
LanguageEnglish

Related product manuals