- 105 -
OUTDOOR UNIT
AOYG18-54LB
9. Electrical characteristics
*1: Maximum current is the total current of the indoor unit and the outdoor unit.
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate
devices complied to the regional standard.
*3: Limit voltage drop to less than 2%. Increase conductor size if voltage drop is 2% or more.
Model name AOYG18LBCA AOYG24LBCA AOYG30LBTA AOYG36LBTA
Power
supply
Voltage V 230 ~
Frequency Hz 50
Max operating current *1 A 13.5 18.5 17.0 20.0
Wiring
spec. *2
Circuit breaker
current
A25 30
Power cable
mm
2
4.0
Connection
cable *3
mm
2
1.5 — 2.5
Limited
wiring
length
m31 51
Model name AOYG45LBTA AOYG54LBTA
Power supply Voltage V 230 ~
Frequency Hz 50
Max operating current *1 A 22.5 23.5
Wiring spec.
*2
Circuit breaker current A 30
Power cable
mm
2
6.0
Connection cable *3
mm
2
1.5 — 2.5
Limited wiring
length
m51