- 13 -
DUCT TYPE
ARYG18-54LHTBP
Remote controller type Wired
NOTES:
Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.), Standard static pressure; 36 type: 47Pa, 45 type and 54 type: 60Pa
Protective function might work when using it outside the operation range.
*1: Maximum current:
– The maximum value when operated within the operation range.
– The total current of indoor unit and outdoor unit.
*2: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Model name
ARYG36LHTBP
Energy efficiency class
Cooling
A
+
Heating (Average) A
Pdesign
Cooling
kW
9.4 (35°C)
Heating (Average) 8.7 (-10°C)
SEER Cooling
kWh/kWh
5.81
SCOP Heating (Average) 3.81
Annual energy consumption
QCE
kWh/a
566
QHE (Average) 3,194
Sound power level
Cooling
HIGH dB(A)
64
Heating 63
Type
Duct
Inverter heat pump
Model name