2. MODEL SELECTION
MODEL : AS
 
G07LUCA
Outdoor Temperature
Indoor temperature (°CDB)
16.0 18.0 20.0 24.0 26.0
(°CDB) (°CWB) TC TC TC TC TC
-15.0 -16.0 1.86 1.72 1.59 1.46 1.30
-10.0 -11.0 2.08 1.93 1.78 1.64 1.46
-5.0 -7.0 2.31 2.14 1.98 1.82 1.62
0.0 -2.0 2.53 2.34 2.16 1.99 1.77
5.0 3.0 2.71 2.51 2.32 2.13 1.90
7.0 6.0 2.77 2.57 2.37 2.18 1.94
10.0 8.0 2.77 2.57 2.37 2.18 1.94
15.0 10.0 2.77 2.57 2.37 2.18 1.94
20.0 15.0 2.77 2.57 2.37 2.18 1.94
MODEL : AS
 
G09LUCA
Outdoor Temperature
Indoor temperature (°CDB)
16.0 18.0 20.0 24.0 26.0
(°CDB) (°CWB) TC TC TC TC TC
-15.0 -16.0 2.34 2.17 2.00 1.84 1.64
-10.0 -11.0 2.62 2.43 2.24 2.06 1.84
-5.0 -7.0 2.92 2.71 2.49 2.29 2.04
0.0 -2.0 3.19 2.96 2.72 2.51 2.23
5.0 3.0 3.42 3.17 2.92 2.69 2.40
7.0 6.0 3.50 3.24 2.99 2.75 2.45
10.0 8.0 3.50 3.24 2.99 2.75 2.45
15.0 10.0 3.50 3.24 2.99 2.75 2.45
20.0 15.0 3.50 3.24 2.99 2.75 2.45
MODEL : AS
 
G12LUCA
Outdoor Temperature
Indoor temperature (°CDB)
16.0 18.0 20.0 24.0 26.0
(°CDB) (°CWB) TC TC TC TC TC
-15.0 -16.0 3.10 2.88 2.65 2.44 2.18
-10.0 -11.0 3.47 3.22 2.97 2.73 2.44
-5.0 -7.0 3.86 3.58 3.30 3.04 2.71
0.0 -2.0 4.22 3.91 3.61 3.32 2.96
5.0 3.0 4.53 4.20 3.87 3.56 3.17
7.0 6.0 4.63 4.30 3.96 3.64 3.25
10.0 8.0 4.63 4.30 3.96 3.64 3.25
15.0 10.0 4.63 4.30 3.96 3.64 3.25
20.0 15.0 4.63 4.30 3.96 3.64 3.25
MODEL : AS
 
G14LUCA
Outdoor Temperature
Indoor temperature (°CDB)
16.0 18.0 20.0 24.0 26.0
(°CDB) (°CWB) TC TC TC TC TC
-15.0 -16.0 3.76 3.49 3.22 2.96 2.64
-10.0 -11.0 4.21 3.91 3.60 3.31 2.95
-5.0 -7.0 4.68 4.34 4.00 3.68 3.28
0.0 -2.0 5.12 4.74 4.37 4.02 3.59
5.0 3.0 5.49 5.09 4.69 4.31 3.85
7.0 6.0 5.62 5.21 4.80 4.42 3.94
10.0 8.0 5.62 5.21 4.80 4.42 3.94
15.0 10.0 5.62 5.21 4.80 4.42 3.94
20.0 15.0 5.62 5.21 4.80 4.42 3.94
HEATING CAPACITY
TC : Total Capacity kW.
The data is based on the following conditions.
Pipe length : 5m [Outdoor unit - Branch box], 3m [Branch box - Indoor unit]
Height difference : 0m [Outdoor unit - Indoor unit].
- (02 - 33) -
MODEL
SELECTION
MODEL
SELECTION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASHG14LMCA and is the answer not in the manual?

Fujitsu ASHG14LMCA Specifications

General IconGeneral
BrandFujitsu
ModelASHG14LMCA
CategoryAir Conditioner
LanguageEnglish

Related product manuals