En-5
4. BASIC OPERATIONS
■
3 steps to start operation
1.
Press
to start or stop the operation.
2.
Press
to select the operation mode.
The operation mode changes as follows.
(Auto) (Cool) (Dry) (Fan) (Heat)
3.
Press
to set the desired temperature.
The temperature changes by 0.5 °C increments.
Temperature setting range
Auto/Cooling/Dry 18.0-30.0 °C
Heating 16.0-30.0 °C
NOTES:
• In the Cooling or Dry mode, set the temperature lower than the
current room temperature.
• In the Heating mode,
- set the temperature higher than the current room temperature.
- at the beginning of the operation, the indoor unit fan rotates at very
low speed for 3-5 minutes.
- the Automatic defrosting operation overrides the Heating operation
when necessary.
• In the Fan mode, temperature control is not available.
5. AIRFLOW SETTINGS
5.1. Fan speed setting
Press to control the fan speed.
The fan speed changes as follows.
(Auto) (Quiet) (Low) (Med) (High)
When
is selected, the fan speed depends on the operating
condition.
NOTE:
In the Dry mode, the fan speed is fi xed to
.
5.2. Airfl ow direction setting
For details of the airfl ow ranges, refer to “Airfl ow direction
range”.
■ Up/down airflow direction setting
Press to adjust the Up/down airfl ow direction.
■ Left/right airflow direction setting
Press to adjust the Left/right airfl ow direction.
■ Swing operation setting
Press to select the Swing operation.
The Swing operation changes as follows.
Up/down Left/right Up/down/left/right Stop swing
NOTE:
The Swing operation may stop temporarily when the indoor unit
fan is rotating at very low speed or is stopped.
■ Airfl ow direction range
Up/down airfl ow direction
1
2
3
4
5
6
Change by
Cooling, Dry 1
⇄
2
⇄
3
(
⇄
4
⇄
5
⇄
6)
Heating, Fan 1
⇄
2
⇄
3
⇄
4
⇄
5
⇄
6
Swing operation by
Cooling, Dry 1 4
Heating 3 6
Fan * 1 4 or 3 6
* The Swing operation range depends on the airfl ow direction set before
the Swing operation.
NOTES:
• Do not adjust the horizontal louvers by hand.
• In the Auto or Heating mode, the airfl ow direction stay position 1 for
a while from the start of the operation.
• In the Cooling or Dry mode, the downward airfl ow can change to
the upper as follows. This feature is to prevent condensation from
dripping and damaging your property.
Condition: Position 4-6 keeps for 30 minutes
Airfl ow adjusted to: Position 3
Left/right airfl ow direction
3
4
5
2
1
Change by
1
⇄
2
⇄
3
⇄
4
⇄
5
Swing operation
by
15
NOTE:
In the Auto mode operation, you cannot change the airflow
direction for a while from the start of the operation.
6. TIMER OPERATIONS
NOTE:
When [
] indicator on the indoor unit blinks, set the timer
again. This blinking shows that the internal clock go wrong due
to an interruption of the power supply. (Refer to page 8.)
■
Timer setting procedure
1.
Press
to choose timer operation.
Each time you press the button, the timer operation will
change as follows:
Off timer
Stops the operation at your desired
time.
On timer
Starts the operation at your desired
time.
Program timer
Operates as the combination of the
On timer and Off timer.
Cancel Deactivate the timer.
•
If you choose “Cancel”, the display returns to the operation
display.
•
To set sleep timer, press . (Refer to “6.3. Sleep
timer”.)
2.
Set each timer operation.
For details, refer to the following instructions of each timer
setting.
9387602319-01_OM_EN.indd 59387602319-01_OM_EN.indd 5 2022/3/11 10:22:122022/3/11 10:22:12