01 - 13
-
MULTI TYPE
3-4ROOMS TYPE
MULTI TYPE
3-4ROOMS TYPE
ARU9RML ARU12RML ARU18RML
kW 2.80 3.50 5.20
BTU/h 9500 12000 17800
kW 1.50-3.30 1.50-4.00 1.80-5.60
BTU/h 5100-11300 5100-13600 6100-19000
kW 3.20 4.10 6.00
BTU/h 11000 14000 20500
kW 1.50-3.80 1.50-4.50 1.60-6.70
BTU/h 5100-13000 5100-15400 5500-23000
pints/h (l/h) 1.9 ( 0.9 ) 2.5 ( 1.2 ) 3.4 ( 1.6 )
High 294 ( 500 ) 412 ( 700 ) 494 ( 840 )
Med 241 ( 410 ) 377 ( 640 ) 412 ( 700 )
Low 218 ( 370 ) 324 ( 550 ) 377 ( 640 )
Quiet
High 294 ( 500 ) 412 ( 700 ) 494 ( 840 )
Med 241 ( 410 ) 377 ( 640 ) 412 ( 700 )
Low 218 ( 370 ) 324 ( 550 ) 377 ( 640 )
Quiet
SIROCCO × 1 SIROCCO × 2 SIROCCO × 2
W11 21 21
in.WG ( Pa )
High 39 ( 34 ) 36 ( 33 ) 40 ( 36 )
Med 35 ( 30 ) 34 ( 30 ) 36 ( 34 )
Low 32 ( 27 ) 31 ( 28 ) 34 ( 32 )
Quiet
High 39 ( 34 ) 36 ( 33 ) 40 ( 36 )
Med 35 ( 30 ) 34 ( 30 ) 36 ( 34 )
Low 32 ( 27 ) 31 ( 28 ) 34 ( 32 )
Quiet
———
———
———
———
FPI 18 20 20
3 × 14 2 × 14 3 × 14
8-35/64 x 25-5/8 x 23-1/2
( 217 × 650 × 596 )
12-3/4 x 20-29/32 x 27
( 324 x 785 x 686 )
40 (18)
48 (22)
LIQUID
GAS Φ 1/2 (12.7)
°F (°C)
%RH
°F (°C)
60 to 88 ( 16 to 31 )
FAN
AIR FLOW
RATE
MATERIAL
COLOR
ROWS x STAGES
PIPE TYPE
HEAT
EXCHANGER
TYPE
dB(A)
FIN TYPE
ENCLOSURE
SOUND PRESSURE
LEVEL
Non Measuring duct
(Set the Measuring duct 1)
COOLING
HEATING
DIMENSION
(H × W × D)
FIN PITCH
OUTER DIAMETER Φ 1-1/32 (26.0)
TYPE
MODEL NAME
POWER SOURCE
AVAILABLE VOLTAGE RANGE
DRAIN PIPE
DIMENSIONS
(H × W × D)
CONCEALED CEILING MODELS
REMOTE CONTROLLER TYPE
WEIGHT
INNER DIAMETER Φ 27/32 (21.5)
PS
INVERTER HEAT PUMP TYPE
ALUMINUM
230/208V ~ 60Hz
187-253V ~ 60Hz
( 324 x 1075 x 686 )
55 (25)
-
COOLING
MOISTURE REMOVAL
CAPACITY
HEATING
RATED
MIN.-MAX.
RATED
MIN.-MAX.
MOTOR OUTPUT
CFM
(m
3
/h)
COOLING
HEATING
TYPE x Q'ty
in. (mm)
8-35/64 × 37-1/64 × 23-1/2
(217 × 940 × 596)
12-3/4 x 42-5/16 x 27
GALVANIZED STEEL SHEET
COPPER TUBE
11-9/16 x 27-9/16 x 1-9/16
( 294 × 700 × 39.9 )
11-9/16 x 27-9/16 x 1-1/16
( 294 × 700 × 26.6 )
11-9/16 x 16-5/32 x 1-9/16
( 294 × 410 × 39.9 )
NET
in. (mm)
NET
GROSS
lb. (Kg)
SIZE
METHOD
MATERIAL
WIRED
Φ 1/4 (6.35)
OPERATION RANGE
COOLING
64 to 90 ( 18 to 32 )
80 or less
HEATING
64 (29)
Φ 3/8 (9.52)
in. (mm)
RECOMMENDED STATIC PRESSURE 0 - 0.16 ( 0 to 40 )
FLARE
SIZE
GROSS
CONNECTION PIPE
in. (mm)
Note:
Specifications are based on the following conditions.
Power source of specifications : 230V
Cooling: Indoor temperature of 80°F (26.7°C) DB / 67°F (19.4°C) WB,and outdoor temperature of 95°F (35°C) DB/75°F (23.9°C) WB.
Heating: Indoor temperature of 70°F (21.1°C) DB / 60°F (15.6°C) WB,and outdoor temperature of 47°F (8.3°C) DB/43°F (6.1°C) WB.
Pipe length : 24ft. 7in.(7.5m),Height difference : 0 ft.(0m) [Outdoor unit - Indoor unit]
1:Detail is in 8-2-2.CONCEALED CEILING TYPE.
3-2. CONCEALED CEILING TYPE