02 - 14
)
-
OUTDOOR UNIT
AOU36R
OUTDOOR UNIT
AOU36R
10. SAFETY DEVICES
Current fuse
(NEAR THE TERMINAL)
Fan motor protection Temperature Thermistor
212
+27
-18
°F OFF
203
+27
-18
°F ON
100
+15
-10
°C OFF
95
+15
-10
°C ON
Compressor protection Temperature Thermistor
257
±4
°F OFF
176
±4
°F ON
125
±2
°C OFF
80
±2
°C ON
Refrigerant circuit protection Pressure switch (1)
609
±15
PSI OFF
464
±22
PSI ON
4.2
±0.1
MPa OFF
3.2
±0.15
MPa ON
Pressure switch (2) : For control device
Circuit protection
Protection form
5A 250V
Current fuse
(MAIN PCB)
10A 250V
Model
AOU36R
3.15A 250V