5-2. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: ASUG09LZAS
AFR CFM 542
Indoor temperature
°FDB 60 65 70 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP
kBtu kW kBtu kW kBtu kW kBtu kW
-5 -7 14.7 2.01 14.3 2.05 14.0 2.09 13.3 2.17
5 3 16.1 2.02 15.7 2.06 15.4 2.10 14.6 2.19
14 12 16.8 1.98 16.4 2.02 16.0 2.07 15.2 2.15
23 19 18.3 1.95 17.9 1.99 17.5 2.03 16.6 2.11
32 28 18.8 1.91 18.4 1.95 17.9 1.99 17.0 2.07
41 37 21.3 1.88 20.8 1.92 20.3 1.95 19.3 2.03
47 43 23.1 1.85 22.6 1.89 22.0 1.93 20.9 2.01
50 47 25.5 1.84 24.9 1.88 24.3 1.91 23.1 1.99
59 50 26.5 1.63 25.8 1.67 25.2 1.70 23.9 1.77
AFR
m
3
/h
920
Indoor temperature
°CDB 15.6 18.3 21.1 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP
kW kW kW kW
-20.6 -21.7 4.31 2.01 4.20 2.05 4.10 2.09 3.90 2.17
-15.0 -16.1 4.73 2.02 4.61 2.06 4.50 2.10 4.28 2.19
-10.0 -11.1 4.91 1.98 4.80 2.02 4.68 2.07 4.45 2.15
-5.0 -7.2 5.38 1.95 5.25 1.99 5.12 2.03 4.86 2.11
0.0 -2.2 5.52 1.91 5.39 1.95 5.26 1.99 5.00 2.07
5.0 2.8 6.25 1.88 6.10 1.92 5.95 1.95 5.65 2.03
8.3 6.1 6.77 1.85 6.61 1.89 6.45 1.93 6.13 2.01
10.0 8.3 7.48 1.84 7.30 1.88 7.13 1.91 6.77 1.99
15.0 10.0 7.75 1.63 7.57 1.67 7.38 1.70 7.02 1.77
¢
Model: ASUG12LZAS
AFR CFM 542
Indoor temperature
°FDB 60 65 70 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP
kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW
-5 -7 15.8 2.01 15.4 2.05 15.0 2.09 14.3 2.17
5 3 17.4 2.02 17.0 2.06 16.6 2.10 15.8 2.19
14 12 18.3 1.98 17.8 2.03 17.4 2.07 16.5 2.15
23 19 20.0 1.95 19.5 1.99 19.0 2.03 18.1 2.11
32 28 20.6 1.92 20.1 1.96 19.6 2.00 18.6 2.08
41 37 22.5 1.88 21.9 1.92 21.4 1.96 20.3 2.04
47 43 23.2 1.86 22.7 1.90 22.1 1.94 21.0 2.02
50 47 25.6 1.85 25.0 1.89 24.4 1.93 23.2 2.00
59 50 26.6 1.64 25.9 1.68 25.3 1.71 24.0 1.78
AFR
m
3
/h
920
Indoor temperature
°CDB 15.6 18.3 21.1 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP
kW kW kW kW
-20.6 -21.7 4.63 2.01 4.52 2.05 4.41 2.09 4.19 2.17
-15.0 -16.1 5.11 2.02 4.99 2.06 4.86 2.10 4.62 2.19
-10.0 -11.1 5.36 1.98 5.23 2.03 5.10 2.07 4.85 2.15
-5.0 -7.2 5.86 1.95 5.72 1.99 5.58 2.03 5.30 2.11
0.0 -2.2 6.03 1.92 5.88 1.96 5.74 2.00 5.45 2.08
5.0 2.8 6.58 1.88 6.43 1.92 6.27 1.96 5.96 2.04
8.3 6.1 6.80 1.86 6.64 1.90 6.48 1.94 6.15 2.02
10.0 8.3 7.52 1.85 7.34 1.89 7.16 1.93 6.80 2.00
15.0 10.0 7.79 1.64 7.60 1.68 7.42 1.71 7.05 1.78
- 11 -
5-2. Heating capacity 5. Capacity table
WALL MOUNTED
ASUG09-15LZAS
WALL MOUNTED
ASUG09-15LZAS