11. Safety devices
Type of
protection
Protection form
Model
AOUG09LZAS1 AOUG12LZAS1 AOUG15LZAS1
Circuit
protection
Current fuse (Main PCB)
250 V, 15 A 250 V, 20 A
250 V, 5 A
250 V, 3.15 A
Fan motor
protection
Thermal protection program
Activate
257±18 °F (125±10 °C)
Fan motor stop
Reset
248±18 °F (120±10 °C)
Fan motor restart
Compressor
protection
Thermal protection program
(Compressor temp.)
Activate
226 °F (108 °C)
Compressor stop
Reset
After 3 minutes, and 176 °F (80 °C) or less
Compressor restart
Thermal protection program
(Discharge temp.)
Activate
230 °F (110 °C)
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection program
(Outdoor temp.)
(Only in COOL and DRY mode)
Activate
5 °F (-15 °C)
Compressor stop
Reset
14 °F (-10 °C)
Compressor restart
- 69 -
11. Safety devices
OUTDOOR UNIT
AOUG09-15LZAS1
OUTDOOR UNIT
AOUG09-15LZAS1

Table of Contents

Other manuals for Fujitsu ASUG12LZAS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASUG12LZAS and is the answer not in the manual?

Fujitsu ASUG12LZAS Specifications

General IconGeneral
BrandFujitsu
ModelASUG12LZAS
CategoryAir Conditioner
LanguageEnglish

Related product manuals