Error status
Function
setting /
Rotary SW of External
input and output PCB
External output Output signal Command
60-09 / B Output of indoor unit CN47
Low → High Error
High → Low Normal
60-00 / 2
60-01 / 3
60-02 / 4
60-04 / 6
60-05 / 7
60-06 / 8
60-07 / 9
External input and output
PCB
Output 1
Off → On Error
On → Off Normal
60-00 / 1
Output 2
Off → On Error
60-10 / C
On → Off Normal
60-11 / D Output 3
Off → On Error
On → Off Normal
The output is ON when an error is generated for the indoor unit.
Error
Normal
High
Low
CN47
On
Off
Output 1, 2, 3
Indoor unit
- 96 -
11-4. Details of function 11. External input and output (Compact cassette type and slim duct type indoor unit)