10. Electrical characteristics
Model name AOYA09KLWA and AOYA12KLWA
Power
supply
Voltage V 230 ~
Frequency Hz 50
Max operating current *1 A 10
Wiring
spec. *2
Circuit breaker current A 10
Power cable
mm
2
1.5
Connection cable
*3
Cross-sectional area
mm
2
1.5
Limited wiring length m 26
*1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate de-
vices complied to the regional standard.
*3: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor size.
- 31 -
10. Electrical characteristics
OUTDOOR UNIT
AOYA09-12KLWA
OUTDOOR UNIT
AOYA09-12KLWA