Dimensions
(H × W × D)
Net
mm
805x194x285
Gross 870x285x360
Weight
Net
kg
7.6
Gross 9.7
Connection pipe
Liquid
mm (in)
φ
6.35 (
φ
1/4)
Gass
φ
9.52 (
φ
3/8)
Method Flare
Drain hose
Material PE
Size mm
φ
16
Operation range
Cooling
°C 17-32
%RH 80 or less
Heating °C 0-30
Remote controller type Wireless
Energy efficiency class
Cooling A++
Heating (Average) A+
Pdesign
Cooling
kW
2.6 3.5
Heating (Average) 2.1 2.3
SEER Cooling
kWh/kWh
6.2 6.1
SCOP Heating (Average) 4.0 4.0
Annual energy consumption
QCE
kWh/a
147 201
QHE (Average) 735 822
Sound power level
Cooling
dB (A)
53 53
Heating 54 54.5
Notes:
1) Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19 °C(66.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
-Outdoor Temperature 35 °C(95°F) DB /24 °C(75.2°F) WB -Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
-Interconnecting Piping Length 5m - Interconnecting Piping Length 5 m
- Level Difference of Zero. - Level Difference of Zero.
2) Protective function might work when using it outside the operation range
3) Sound pressure level was measured in anechoic chamber, the sound level measured in actual installation conditions
might be higher than the specified values here.
4) Due to our policy of innovation some specifications may be changed without notification.