REPLACEMENT PARTS
09-36
Model : AOYR30LCT
PROCESS
Fig.1
W25 ORANGE W26 ORANGE
(FILTER PWB)
WIRE WITH TERMINAL
W28 ORANGE (FILTER PWB)
WIRE WITH TERMINAL
W25 and W26 must do the twist
13 times from 10 times
W29 BROWN(FILTER PWB)
WIRE WITH TERMINAL
W28 and W29 must do the twist
13 times from 10 times
The point must become complete in each wire
that does the twist.
Connect WIRE WITH TERMINAL
(THERMISTOR)
REGULATIONS
As shown Fig.3, connect wires.
A right picture shows the example of two times of the twist.