5. INDOOR FAN CONTROL
(1).Fan speed
( Table 5 : Indoor Fan Speed )
ASYA24LCC
Operation mode Air flow mode Speed (rpm)
Hi 1,310
Me+ 1,220
Me 1,120
Lo 940
Quiet 830
Cool air
prevention
650
Heating
S-Lo 250
Hi 1,310
Me 1,120
Lo 940
Cooling
Fan
Quiet 830
Dry 830
ASYA30LCC
Operation mode Air flow mode Speed (rpm)
Hi 1,330
Me+ 1,220
Me 1,120
Lo 940
Quiet 830
Cool air
prevention
650
Heating
S-Lo 250
Hi 1,330
Me 1,120
Lo 940
Cooling
Fan
Quiet 830
Dry 830
(2).FAN OPERATION
The airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH, while the indoor
fan only runs.
When Fan mode is set at (Auto), it operates on (MED) Fan Speed.
05-05
(3).COOLING OPERATION
Switch the airflow [AUTO], and the (Fig.6)
indoor fan motor will run according airflow change - over ( Cooling:AUTO )
to a room temperature, as shown in When the room
Figure 6. temperature rises
On the other hand, if switched in HIGH mode
[HIGH] [QUIET], the indoor motor
will run at a constant airflow of [COOL]
operation modes QUIET, LOW, MED, MED mode
HIGH, as shown in Table 5.
When the room
temperature lowers
(Room temperature) D (Setting temperature)
+1.0 C
LOW mode
+2.0 C
+2.5 C
+1.5 C