REPLACEMENT PARTS
09-38
Model : AOYR30LCT
PROCESS
Fig.1
W12 WHITE
(CAPACITOR PWB)
WIRE WITH TERMINAL
Connect it surely.
W13 VIOLET
(CAPACITOR PWB)
WIRE WITH TERMINAL
ACTPM
W7 YELLOW W8 BLUE
(CAPACITOR PWB)
WIRE WITH CONNECTOR
P(WHITE)
N(VIOLET)
W301 YELLOW W302 BLUE
(TR PWB)
WIRE WITH CONNECTOR
TR PWB ASSY
W29 BROWN(FILTER PWB)
WIRE WITH TERMINAL
W28 ORANGE(FILTER PWB)
WIRE WITH TERMINAL
TM102
TM101
W28 and W29 must do the twist
13 times from 10 times
W12 and W13 must do the twist
9 times from 6 times
Connect wires.
(PWB ASSY(CAPACITOR),TR PWB ASSY,etc)
REGULATIONS
As shown in Fig.1, connect wires.
A right picture shows the example of two times of the twist.