08-08
Heating
*Defrosting operation is performed when temperature is less than 7 degrees C.
Frost appears on an outdoor unit heat exchanger at 7 or less degrees C.
*Solid line:Integral capacity/Input containing the defrosting cycle.
*Dotted line:Capacity/Input which does not contain the defrosting cycle.
*The Capacity and the input change as the current limit value varies with the outdoor temperature.
<Capacity>
<Input>
40%
50%
60%
70%
80%
90%
100%
110%
120%
130%
140%
-15 -10 -5 0 5 10 15 20
Outdoor DB ( C)
Capacity (%)
7 12 17 24
Indoor DB : 20 C
Maximum
operation
Maximum
operation
Maximum operation
(Without Frost)
Maximum operation
(With Frost)
Rated
operation
60%
70%
80%
90%
100%
110%
120%
130%
140%
150%
160%
170%
180%
-15 -10 -5 0 5 10 15 20
Outdoor DB ( C)
Input (%)
7 12 17 24
Maximum
operation
Maximum
operation
Maximum operation
(Without Frost)
Maximum operation
(With Frost)
Rated
operation
ASYA30LCC Capacity/Input data
o
Indoor DB : 20 C
o
o
o
1/2