REPLACEMENT PARTS
09-26
PROCESS ATTACHMENT OF INVERTER ASSY
4way valve lead
Gather lead wires with the binder.
Hole
5 leads from PCB
PCB side
Binder TOP direction
30
30
Signal Line
Do not let each thermistor lead wires (discharge,
outdoor temperature, heat exchanger) step over
the signal wire.
Binder location
Height upon gathering
E - E
E
E
C
F
F
D
F - F
each wire
Distance between Inverter
case bottom and EMI
30~50
10~20
20~30
40~60
Binder location
Gathering location
Spec. of Slack for
4way valve lead.
Gather 4way
valve lead
of inverter case
bottom and 4way
valve lead.
0~10
20~30
10~20
4way valve lead height
20~30
Motor lead height
1
1
1
Model : AOYR24LCC