11. Safety devices
Type of
protection
Protection form
Model
AOYG07KPCA AOYG09KPCA AOYG12KPCA
Circuit protection Current fuse (Main PCB)
250 V, 20 A
250 V, 5 A
Fan motor
protection
Thermistor protection
Activate
85—122 °C
Fan motor stop
Reset
77—114 °C
Fan motor restart
Compressor
protection
Terminal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection
program
(Outdoor temp.)
Activate
COOL or DRY: -15 °C
HEAT: -20 °C
Compressor stop
Reset
COOL or DRY: -10 °C
HEAT: -15 °C
Compressor restart