9-2. External output
With using external output function, operating status of this product can be transmitted to the ex-
ternal device, and also, this product can be inter-connected with the external device.
¢
Operation status output
Air conditioner operation status signal can be output.
Circuit diagram example
Locally purchasedOptional parts
Example: Display
Indoor unit
control PCB
Communication kit Connected unit
Example: Relay unit
1
2
Signal
Relay
power supply
V
Connector
10 m*
DC 24 V
*: Make the distance from the PCB to the connected unit within 10 m.
Relay spec: Max. DC 24 V, 10 mA to less than 500 mA.
On
Off
Operation
Stop
Indoor unit
Output signal
Optional part
Part name Model name Exterior
External connect kit UTY-XWZXZ5
External output wire
Communication kit UTY-XCBXZ2
* For operating the external function, the wall mounted type requires the communication kit in
addition to the wire (UTY-XWZXZ5).
- 21 -
WALL MOUNTED
ASYG07-14LMCE

Table of Contents

Other manuals for Fujitsu ASYG07LMCE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG07LMCE and is the answer not in the manual?

Fujitsu ASYG07LMCE Specifications

General IconGeneral
TypeAir conditioner indoor unit
TimerYes
Ionizer-
Multi-splitNo
Hose diameter6.35 mm
Product colorWhite
Gas hose diameter9.52 mm
Drain hose diameter13.8 mm
Dehumidifying capacity1 l/h
Air conditioner functionsCooling, Heating
Cooling capacity in watts (max)3000 W
Cooling capacity in watts (min)500 W
Heating capacity in watts (max)3400 W
Cooling capacity in watts (nominal)2000 W
Heating capacity in watts (nominal) (Warmer heating season)- W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4.1
Current7.5 A
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)2 kW
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)2.3 kW
Indoor unit typeWall-mountable
Indoor unit depth204 mm
Indoor unit width870 mm
Indoor unit height270 mm
Indoor unit weight8500 g
Indoor units quantity1
Heating airflow (indoor unit)750 m³/h
Indoor unit sound power level40 dB
Indoor unit noise level (low speed)32 dB
Indoor unit noise level (high speed)43 dB
Outdoor unit noise level- dB