EasyManuals Logo

Fujitsu ASYG09KMTA Design & Technical Manual

Fujitsu ASYG09KMTA
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Outdoor units installation in multi-row
Unit: mm
Single parallel unit arrangement Multiple parallel unit arrangement
100 or more
200 or more
500 or more
1,000 or more
200 or more
400 or more
1,000 or more
250 or more
2,000 or more
250 or more
1,000 or more
200 or more
250 or more
200 or more
NOTES:
If the space is larger than stated above, the condition will be the same as when there is no
obstacle.
When installing the outdoor unit, be sure to open the front and left side to obtain better opera-
tion efficiency.
CAUTION
Do not install the outdoor unit in two-stage where the drain water could freeze. Otherwise the
drainage from the upper unit may form ice and cause a malfunction of the lower unit.
When the outdoor temperature is 0 °C or less, do not use the accessory drain pipe and drain
cap. If the drain pipe and drain cap are used, the drain water in the pipe may freeze in ex-
tremely cold climate. (For reverse cycle model only.)
In area with heavy snowfall, if the inlet and outlet of the outdoor unit is blocked with snow, it
might become difficult to get warm, and it is likely to cause product malfunction. Construct a
canopy and a pedestal, or place the unit on a high stand that is locally installed.
- 45 -
OUTDOOR UNIT
AOYG07-14KMTA

Table of Contents

Other manuals for Fujitsu ASYG09KMTA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG09KMTA and is the answer not in the manual?

Fujitsu ASYG09KMTA Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-splitNo
Product colorWhite
Gas hose diameter9.5 mm
Hose length (max)15 m
Inverter technology-
Liquid hose diameter6.35 mm
Comfort sleeping modeYes
Dehumidifying capacity1.3 l/h
Air conditioner functionsCooling, Heating
Cooling capacity in watts (max)3200 W
Cooling capacity in watts (min)900 W
Heating capacity in watts (max)4000 W
Cooling capacity in watts (nominal)2500 W
Cooling energy efficiency (EER, W/W)3.97
Heating energy efficiency (COP, W/W)4.52
Seasonal efficiency rating (cooling) (SEER)7.4
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)2800 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4.1
AC input voltage230 V
Current (cooling)6.5 A
Current (heating)9 A
AC input frequency50 Hz
Design load (cooling)2.5 kW
Energy efficiency class (cooling)A++
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)2.4 kW
Energy efficiency class (heating) (Average heating season)A+
Indoor unit typeWall-mountable
Indoor unit depth222 mm
Indoor unit width834 mm
Indoor unit height270 mm
Indoor unit weight10000 g
Indoor units quantity1
Cooling airflow (indoor unit)700 m³/h
Indoor unit sound power level40 dB
Indoor unit noise level (low speed)29 dB
Indoor unit noise level (high speed)46 dB
Outdoor unit noise level- dB