4. Capacity table
Capacity tables show each of following values calculated based on the outdoor temperature and the
indoor temperature, under given Airflow Rate (AFR):
For cooling capacity: Total Capacity (TC), Sensible Heat Capacity (SHC), and Input Power (IP)
For heating capacity: Total Capacity (TC) and Input Power (IP)
4-1. Cooling capacity
¢
Models: ASYG07KMTA and ASYG07KMTB
AFR
m
3
/h
650
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-10 2.07 1.20 0.25 2.25 1.25 0.25 2.37 1.28 0.25 2.49 1.31 0.25 2.55 1.35 0.25 2.73 1.37 0.24 2.91 1.42 0.24
0 2.02 1.17 0.29 2.19 1.22 0.28 2.31 1.25 0.28 2.43 1.28 0.28 2.48 1.31 0.28 2.66 1.34 0.27 2.84 1.38 0.27
5 1.91 1.14 0.38 2.07 1.19 0.38 2.18 1.21 0.38 2.29 1.24 0.37 2.34 1.28 0.38 2.51 1.30 0.37 2.68 1.34 0.37
10 1.96 1.13 0.36 2.13 1.17 0.36 2.24 1.20 0.35 2.36 1.23 0.35 2.41 1.27 0.35 2.58 1.29 0.35 2.75 1.33 0.34
15 1.92 1.14 0.36 2.08 1.18 0.35 2.20 1.21 0.35 2.31 1.24 0.35 2.36 1.27 0.35 2.53 1.29 0.34 2.70 1.34 0.34
20 1.86 1.13 0.37 2.02 1.18 0.36 2.13 1.20 0.36 2.24 1.23 0.36 2.29 1.27 0.36 2.46 1.29 0.35 2.62 1.33 0.35
25 1.80 1.12 0.39 1.95 1.16 0.38 2.06 1.19 0.38 2.16 1.22 0.38 2.21 1.25 0.38 2.37 1.28 0.37 2.53 1.32 0.37
30 1.72 1.10 0.42 1.87 1.14 0.41 1.97 1.17 0.41 2.07 1.20 0.41 2.11 1.23 0.41 2.27 1.25 0.40 2.42 1.30 0.40
35 1.63 1.07 0.46 1.77 1.11 0.45 1.86 1.14 0.45 1.96 1.17 0.45 2.00 1.20 0.45 2.15 1.22 0.44 2.29 1.26 0.44
40 1.52 1.03 0.51 1.66 1.07 0.50 1.75 1.10 0.50 1.83 1.13 0.50 1.87 1.16 0.50 2.01 1.18 0.49 2.14 1.22 0.49
46 1.39 0.98 0.59 1.51 1.02 0.58 1.59 1.04 0.58 1.67 1.07 0.57 1.70 1.10 0.58 1.83 1.12 0.57 1.95 1.15 0.56
¢
Models: ASYG09KMTA and ASYG09KMTB
AFR
m
3
/h
700
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-10 2.59 1.60 0.36 2.82 1.66 0.35 2.97 1.70 0.35 3.12 1.74 0.35 3.18 1.79 0.35 3.42 1.83 0.34 3.64 1.89 0.34
0 2.52 1.56 0.40 2.74 1.62 0.40 2.89 1.66 0.39 3.04 1.70 0.39 3.10 1.75 0.39 3.33 1.78 0.38 3.55 1.84 0.38
5 2.38 1.52 0.54 2.59 1.58 0.53 2.73 1.62 0.53 2.87 1.66 0.52 2.93 1.71 0.53 3.14 1.73 0.52 3.35 1.79 0.51
10 2.45 1.51 0.50 2.66 1.57 0.50 2.80 1.60 0.50 2.95 1.64 0.49 3.01 1.69 0.50 3.23 1.72 0.49 3.44 1.78 0.48
15 2.40 1.51 0.50 2.61 1.57 0.50 2.74 1.61 0.49 2.88 1.65 0.49 2.95 1.70 0.49 3.16 1.73 0.48 3.37 1.78 0.48
20 2.33 1.51 0.51 2.53 1.57 0.51 2.67 1.61 0.50 2.80 1.64 0.50 2.86 1.69 0.50 3.07 1.72 0.49 3.27 1.78 0.49
25 2.25 1.49 0.54 2.44 1.55 0.53 2.57 1.59 0.53 2.70 1.63 0.53 2.76 1.67 0.53 2.96 1.70 0.52 3.16 1.76 0.51
30 2.15 1.47 0.58 2.33 1.52 0.58 2.46 1.56 0.57 2.58 1.60 0.57 2.64 1.64 0.57 2.83 1.67 0.56 3.02 1.73 0.56
35 2.03 1.43 0.64 2.21 1.48 0.63 2.33 1.52 0.63 2.45 1.56 0.63 2.50 1.60 0.63 2.68 1.63 0.62 2.86 1.68 0.61
40 1.91 1.38 0.71 2.07 1.43 0.71 2.18 1.47 0.70 2.29 1.50 0.70 2.34 1.54 0.70 2.51 1.57 0.69 2.68 1.62 0.68
46 1.73 1.31 0.82 1.88 1.36 0.81 1.98 1.39 0.81 2.08 1.42 0.80 2.13 1.46 0.81 2.28 1.49 0.79 2.44 1.54 0.78
¢
Models: ASYG12KMTA and ASYG12KMTB
AFR
m
3
/h
700
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-10 3.45 2.30 0.54 3.75 2.37 0.54 3.94 2.42 0.53 4.14 2.46 0.53 4.26 2.52 0.53 4.53 2.56 0.53 4.82 2.63 0.52
0 3.22 2.20 0.70 3.50 2.27 0.69 3.68 2.32 0.69 3.86 2.36 0.69 3.97 2.41 0.68 4.22 2.45 0.68 4.50 2.52 0.68
5 3.06 2.15 0.81 3.32 2.21 0.81 3.49 2.26 0.80 3.66 2.30 0.80 3.77 2.35 0.79 4.01 2.39 0.79 4.27 2.45 0.79
10 3.35 2.31 0.61 3.63 2.38 0.61 3.82 2.43 0.60 4.01 2.47 0.60 4.12 2.53 0.59 4.38 2.57 0.60 4.67 2.64 0.59
15 3.27 2.23 0.67 3.55 2.30 0.67 3.73 2.34 0.66 3.92 2.39 0.66 4.03 2.44 0.65 4.28 2.48 0.65 4.56 2.55 0.65
20 3.17 2.16 0.73 3.44 2.22 0.73 3.62 2.27 0.73 3.80 2.31 0.72 3.91 2.36 0.71 4.16 2.40 0.72 4.43 2.47 0.71
25 3.06 2.10 0.80 3.31 2.16 0.80 3.49 2.20 0.79 3.66 2.25 0.79 3.76 2.30 0.78 4.00 2.33 0.78 4.26 2.40 0.78
30 2.92 2.05 0.88 3.17 2.11 0.87 3.33 2.15 0.87 3.49 2.19 0.87 3.59 2.24 0.86 3.82 2.28 0.86 4.07 2.34 0.85
35 2.76 2.01 0.96 2.99 2.07 0.95 3.15 2.11 0.95 3.30 2.15 0.95 3.40 2.20 0.94 3.62 2.24 0.94 3.85 2.30 0.93
40 2.58 1.98 1.05 2.80 2.04 1.04 2.95 2.08 1.04 3.09 2.12 1.03 3.18 2.17 1.02 3.38 2.21 1.02 3.60 2.27 1.01
46 2.34 1.97 1.16 2.54 2.03 1.15 2.67 2.07 1.15 2.80 2.11 1.14 2.88 2.15 1.13 3.07 2.19 1.13 3.26 2.25 1.12
- 7 -
4-1. Cooling capacity 4. Capacity table
WALL MOUNTED
ASYG07-14KMT
WALL MOUNTED
ASYG07-14KMT