1. COMPRESSOR CONTROL
01-01
1. COMPRESSOR FREQUENCY AT NORMAL START-UP
Compressor frequency soon after starting
is controlled as below.
Maximum
frequency
Compressor
SVB130FJDMC
Time
Forced 40 rps operation
for 60 seconds from start-up
60 sec 240 sec 280 sec 360 sec 400 sec
40 rps
90 rps
77 rps
56 rps
99 rps