PARTS INFORMATION 2
Check Point 1 : Check c onnection
Check Point 2 : Check winding resistance
Check Point 3 : Replace main PCB
W
W
GLASS TERMINAL
V
V
U
U
Inverter compressor
Check terminal connection of Compressor
(loose or incorrect wiring)
Check winding resistance of each terminal
If the resistance value is 0 or infinite, replace Compressor.
If the symptom does not change with above Check 1, 2, replace main PCB.
02-30
Resistance value :
1.91Ω at 20°C