EasyManua.ls Logo

Fujitsu ASYG12KMCB - Inverter Compressor

Fujitsu ASYG12KMCB
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PARTS INFORMATION 2
Check Point 1 : Check c onnection
Check Point 2 : Check winding resistance
Check Point 3 : Replace main PCB
W
W
GLASS TERMINAL
V
V
U
U
Inverter compressor
Check terminal connection of Compressor
(loose or incorrect wiring)
Check winding resistance of each terminal
If the resistance value is 0 or infinite, replace Compressor.
If the symptom does not change with above Check 1, 2, replace main PCB.
02-30
Resistance value :
1.91Ω at 20°C