EasyManua.ls Logo

Fujitsu ASYG12KMCB - Page 7

Fujitsu ASYG12KMCB
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
01-04
4. DRY OPERATION
In dry operation, maximum compressor frequency is defined
by set temperature, and room temperature as below.
Ts+0.5°C
Ts -1.5°C
Ts -0.5°C
Ts+1.5°C
Maximum compressor frequency is defined by zone.
Zone is defined by set temperature and room temperature.
20 rps
16 rps
0 rps
AOYG09KMCBN
X zone
J zone
Y zone
22 rps
18 rps
0 rps
AOYG12KMCBN
X zone
J zone
Y zone
Room temperature drops
Room temperature rises
Ts = Set temperature
26 rps
18 rps
0 rps
AOYG14KMCBN

Other manuals for Fujitsu ASYG12KMCB

Related product manuals