ERROR DETECTION
2012.03.12 13
Error
Serial communication error
Indoor unit PCB model information error
Manual auto switch error
Room temp. sensor error
Indoor unit Heat Ex. Middle temp.sensor error
Indoor unit fan motor error
Indoor unit error
Outdoor unit main PCB model
information error or communication error
Inverter error
Active filter error, PFC circuit error
Trip terminal L error
Display PCB microcomputers communication error
Discharge temp. sensor error
Outdoor unit Heat Ex. liquid temp. sensor error
Outdoor temp. sensor error
Current sensor error
Trip detection
Compressor rotor position detection error
4-way valve error
Discharge temp. error
OPERATION TIMER ECONOMY
1 flash 1 flash
3 2
3 5
4 1
4 2
5 1
5 15
6 2
6 3
6 4
6 5
6 10
7 1
7 3
7 4
8 4
9 4
9 5
9 9
10 1
(0.5s on / 0.5s off)
Rapid flash
(0.1s on
/ 0.1s off)
OPERATION lamp (green)
TIMER lamp
(orange)
ECONOMY
lamp (green)
TROUBLESHOOTING
with the indoor unit display

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG12LLCA and is the answer not in the manual?

Fujitsu ASYG12LLCA Specifications

General IconGeneral
BrandFujitsu
ModelASYG12LLCA
CategoryAir Conditioner
LanguageEnglish

Related product manuals