- 18 -
WALL MOUNTED
ASYG30, 36LMTA
6-2. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
Model: ASYG30LMTA
Model: ASYG36LMTA
AFR
m
3
/h
1,380
Indoor temperature
16 18 20 22 24
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 7.08 3.17 6.91 3.23 6.74 3.30 6.57 3.37 6.40 3.43
-10 -11 7.67 3.17 7.49 3.23 7.30 3.30 7.12 3.37 6.94 3.43
-5 -7 8.88 3.17 8.66 3.23 8.45 3.30 8.24 3.37 8.03 3.43
0 -2 9.83 3.17 9.60 3.23 9.36 3.30 9.13 3.37 8.89 3.43
5 3 10.63 3.17 10.37 3.23 10.12 3.30 9.87 3.37 9.61 3.43
7 6 11.55 3.17 11.28 3.23 11.00 3.30 10.73 3.37 10.45 3.43
10 8 11.90 3.16 11.61 3.22 11.33 3.29 11.05 3.36 10.76 3.42
15 10 11.03 2.53 10.77 2.59 10.51 2.64 10.25 2.69 9.98 2.73
20 15 10.95 1.96 10.69 2.00 10.43 2.04 10.17 2.08 9.91 2.11
24 18 10.87 1.38 10.61 1.41 10.35 1.44 10.09 1.47 9.83 1.49
AFR
m
3
/h
1,380
Indoor temperature
16 18 20 22 24
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 8.54 4.13 8.34 4.21 8.13 4.30 7.93 4.39 7.73 4.47
-10 -11 9.19 4.10 8.97 4.18 8.75 4.27 8.53 4.36 8.31 4.44
-5 -7 10.58 4.08 10.33 4.17 10.08 4.25 9.83 4.34 9.58 4.42
0 -2 11.61 4.04 11.34 4.13 11.06 4.21 10.78 4.29 10.51 4.38
5 3 12.70 4.09 12.40 4.17 12.10 4.26 11.79 4.35 11.49 4.43
7 6 11.76 3.50 11.48 3.57 11.20 3.64 10.92 3.72 10.64 3.79
10 8 12.11 3.49 11.82 3.56 11.54 3.63 11.25 3.71 10.96 3.78
15 10 11.14 2.78 10.88 2.84 10.61 2.90 10.35 2.96 10.08 3.00
20 15 11.06 2.21 10.80 2.25 10.53 2.30 10.27 2.35 10.01 2.38
24 18 10.98 1.63 10.71 1.67 10.45 1.70 10.19 1.74 9.93 1.76