EasyManua.ls Logo

Fujitsu MHV2100AH - READ NATIVE MAX ADDRESS EXT (X27): Option (Customizing)

Fujitsu MHV2100AH
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interface
5-112 C141-E217
(39) READ NATIVE MAX ADDRESS EXT (X’27’): Option (customizing)
Description
This command is used to assign the highest address that the device can initially set
with the SET MAX ADDRESS EXT command. The maximum address is
displayed in the CH, CL, SN registers of the device control register with HOB bit
= 0, 1.
Error reporting conditions
This command is issued with LBA = 0. (ST = 51h, ER= 04h: Aborted command)
At command issuance (I/O registers setting contents)
1F7
h
(CM) 0 0 1 0 0 1 1 1
1F6
h
(DH) 1 L 1 DV xx
1F5
h
(CH) P
1F5
h
(CH) C
1F4
h
(CL) P
1F4
h
(CL) C
1F3
h
(SN) P
1F3
h
(SN) C
1F2
h
(SC) P
1F2
h
(SC) C
1F1
h
(FR) P
1F1
h
(FR) C
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
C: Current
P: Previous
At command completion (I/O registers contents to be read)
1F7
h
(ST) Status information
1F6
h
(DH) 1 L 1 DV xx
1F5
h
(CH) 1
1F5
h
(CH) 0
1F4
h
(CL) 1
1F4
h
(CL) 0
1F3
h
(SN) 1
1F3
h
(SN) 0
1F2
h
(SC) 1
1F2
h
(SC) 0
1F1
h
(ER)
Native max address LBA (47-40)
Native max address LBA (23-16)
Native max address LBA (39-32)
Native max address LBA (15-8)
Native max address LBA (31-24)
Native max address LBA (7-0)
xx
xx
Error information
0: HOB=0
1: HOB=1

Table of Contents

Related product manuals