Loading...
Brocade 5450 Embedded Switch Module QuickStart Guide 15 of 20
Publication Number: 53-1001265-02
Connecting the Embedded Switch Module through an external port
Use the following procedure to establish an Ethernet connection through an external port.
NOTE
Ensure that the Embedded Switch Module is not being modified from any other connection until configuration is
complete.
1. Connect an Ethernet cable to the Management LAN port on the Embedded Switch Module faceplate.
2. Click Connection Blades Status in the middle pane of the PRIMERGY BX900 Management Blade GUI to expand
the list.
3. Select FC Connection Blade from the Connection Blade Status in the middle pane, shown in Figure 9.
FIGURE 9 PRIMERGY BX900 Management Blade application - FC connection blade
The current FC Connection Blade information displays.
4. Click the Configuration tab in the middle pane.
5. Scroll down to the Management Port Control section, shown in Figure 10.
FIGURE 10 PRIMERGY BX900 Management Blade application - management port control
6. Select External Port from the Management Port list.
7. Cl ic k Apply.
NOTE
Refer to the PRIMERGY BX900 Management Blade User Guide for additional details.