68 Operating Manual RX300 S7
Starting up and operation
6.1.1.3 Indicators on the drives
Optical drive activity indicator
Lights up green when the storage medium is being accessed.
Hard disk drive indicators
Figure 7: Indicators on the 3.5 inch and 2.5 inch HDD modules
1LED
green
HDD BUSY
Lights up: HDD in active phase
Does not light: HDD inactive (drive inactive)
2LED
orange
HDD FAULT (orange)
(in conjunction with a RAID controller)
Does not light: no HDD error
Lights up: HDD Faulty or Rebuild Stopped (drive
defective/needs replacing, a rebuild process was stopped or
the HDD module is not correctly inserted)
Slow flashing: HDD Rebuild (the data is being restored after
changing a drive)
Fast flashing: HDD Identify
12 21