TX140 S2 Operating Manual 65
Starting up and operation
6.2.1.3 Indicators on the control panel
Power indicator (two-color)
Glows green when the server is switched on.
Lights up orange when the server is switched OFF, but mains
voltage is present (standby mode).
HDD / SSD activity indicator (green)
Lights up green when an internal hard disk drive is accessed.
Global Error indicator (orange)
Lights up orange if a prefailure event has been detected that
requires (precautionary) service intervention.
Flashes orange if an error was detected that requires service
intervention.
Does not light up if there is no critical event.
If the event is still acute after a power failure, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), on the local diagnostic indicators, in the
ServerView Operations Manager or via the iRMC S4's Web
interface.
!