Heating mode
F zone
19°C
E zone
5°C
D zone
0°C
C zone
B zone
A zone
-15°C
-25°C
Model name Outdoor temperature zone
Limitation of compressor
frequency
ROG09KMCDN
A zone 45 rps
B zone 25 rps
C zone 17 rps
D zone 10 rps
E zone 1 rps
F zone 1 rps
ROG12KMCDN
A zone 43 rps
B zone 25 rps
C zone 17 rps
D zone 10 rps
E zone 1 rps
F zone 1 rps
ROG14KMCDN
A zone 36 rps
B zone 31 rps
C zone 20 rps
D zone 14 rps
E zone 1 rps
F zone 1 rps
1-5. Compressor frequency limitation by outdoor temperature - (04-7) - 1. Compressor frequency control