EasyManuals Logo

Fujitsu RSG09KMCDN User Manual

Fujitsu RSG09KMCDN
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
2-2. E: 11. Serial communication error (Serial forward transfer
error) (Indoor unit)
Indicator Indoor unit
Operation indicator 1 time flash
Timer indicator 1 time flash
Economy indicator Continuous flash
Error code E: 11
Detective actuator
Indoor unit
Main PCB
When the outdoor unit cannot properly receive the serial
signal from indoor unit for 10 seconds or more.
Fan motor
Outdoor unit Main PCB
Forecast of cause
Connection failure
External cause
Main PCB failure
Check point 1. Reset the power and operate
Does error indication show again?
→ If no, go to "Check point 1-2".
Check point 2. Check connection
Check any loose or removed connection line of indoor unit and outdoor unit.
→ If there is an abnormal condition, correct it by referring to the installation manual or the “DESIGN
& TECHNICAL MANUAL”.
Check connection condition is control unit. (If there is loose connector, open cable or mis-wiring.)
Check point 3. Check the voltage of power supply
Check the voltage of power supply
Check if AC 207 (AC 230 V -10%) to AC 253 V (AC 230 V +10%) appears at out-
door unit terminal L — N.
+
-
2-2. E: 11. Serial communication error (Serial forward transfer error) (Indoor unit) - (03-4) - 2. Troubleshooting with error code
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu RSG09KMCDN and is the answer not in the manual?

Fujitsu RSG09KMCDN Specifications

General IconGeneral
BrandFujitsu
ModelRSG09KMCDN
CategoryAir Conditioner
LanguageEnglish

Related product manuals