Limit of maximum speed based on outdoor temperature
36°C
A zone
34°C
32°C
B zone
30°C
21°C
C zone
19°C
D zone
E zone
F zone
10°C
0°C
12°C
2°C
Outdoor
temperature drops
Outdoor
temperature rises
Unit: rps
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
RSG09KMCDN
A zone 63 34 24 18
B zone 63 34 24 18
C zone 63 34 24 18
D zone 46 34 24 20
E zone 46 32 24 16
F zone 42 32 24 16
RSG12KMCDN
A zone 63 32 24 16
B zone 63 32 24 16
C zone 63 32 24 16
D zone 42 30 20 12
E zone 42 30 20 12
F zone 42 30 20 12
RSG14KMCDN
A zone 58 30 22 14
B zone 58 30 22 14
C zone 58 30 22 14
D zone 42 28 26 24
E zone 42 28 26 24
F zone 42 28 26 24