This manual must be available to the boiler operator at all times.
RB-RBC-IOMM-2015-1
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
RB / RBC Series
Gas / Oil / Dual Fuel Horizontal Steam Boilers

Table of Contents

Questions and Answers

  • S
    Sherry JenkinsAug 5, 2025
    What to do if FULTON Boiler burner will not start?
    • C
      Crystal HoganAug 5, 2025
      If the FULTON Boiler's burner won't start, you should reset it if the burner control is locked. Also, inspect the ignition electrode, clean or readjust it, and check the transformer.
  • P
    perezcraigAug 9, 2025
    How to fix a FULTON Boiler when gas burner will not start?
    • E
      Erika JonesAug 9, 2025
      If the FULTON Boiler's gas burner doesn't start, check the gas pressure. Also, reset the gas pressure switch. Finally, check the air pressure switch, fan, and thermal overload switch.
  • G
    Gavin MasonAug 14, 2025
    How to troubleshoot poor combustion in FULTON RBC1000?
    • W
      William ArmstrongAug 14, 2025
      If the FULTON Boiler is experiencing poor combustion, start by checking the fuel pressure, fuel valves, and fuel nozzle. Then, readjust the air, check the air inlet, fan, and thermal overload switch. Also, make sure the diffuser alignment is correct in the blast tube and check the flue for any blockage.
  • J
    John RiveraAug 17, 2025
    How to troubleshoot starting problems in FULTON Boiler?
    • J
      Janet SimonAug 17, 2025
      If the FULTON Boiler fails to start, check the fuses or circuit breaker for power supply issues. Ensure there's adequate gas pressure and the main gas cock is open. Inspect the low water probes and check all component connections for loose wires. Also, check the door interlock microswitch if the control circuit is dead.
  • D
    Dale JacobsAug 22, 2025
    Why won't my FULTON Boiler maintain pressure?
    • J
      jordan64Aug 22, 2025
      If the FULTON Boiler is not maintaining pressure, several factors could be at play. Begin by assessing the gas and oil supplies as described earlier. Inspect the steam pressure switch, readjusting or replacing it if needed. Consult with a Water Treatment advisor regarding scale buildup within the boiler. Check the steam traps and replace them if necessary. Ensure the flue side of the boiler is clean and reduce steam overload if present.
  • K
    Kevin LeeAug 27, 2025
    What causes FULTON RBC1000 Boiler oil burner not to start?
    • C
      christopher61Aug 27, 2025
      If the FULTON Boiler's oil burner won't start, check for oil in the storage tank, ensure the oil feed line is open, and inspect the oil solenoid valves. Also, check if the oil pump is de-aerated and inspect the oil strainer.
  • K
    Kristen VasquezAug 30, 2025
    What to do if FULTON Boiler has flame failure?
    • K
      Katherine WalkerAug 31, 2025
      If the FULTON Boiler experiences flame failure, clean or replace the flame sensor. You may also need to check the burner programmer functions or replace it.

Summary

SECTION 2 - INSTALLATION

2.8 STEAM SAFETY VALVE

Emphasizes that safety valves are pre-set and must not be adjusted.

2.9 WATER SUPPLY

Highlights the importance of feedwater quality and recommends consulting a water treatment specialist.

SECTION 3 - OPERATION

3.2.2 STEAM PRESSURE CONTROLS

Describes pressure controls like On/Off, High Limit, and High/Low switches.

3.2.2.1 ADJUSTING STEAM PRESSURE CONTROLS

Step-by-step guide for setting steam pressure controls for optimum performance.

3.2.3 BOILER CONTROL PANEL

Identifies and locates controls and indicators on the boiler control panel.

3.2.4 BURNER CONTROL PANEL

Details typical controls and indicators found on the burner control panel.

3.3 FILLING THE BOILER

Provides a detailed procedure for filling the boiler with water.

3.4 DRAINING THE BOILER

Outlines procedures for draining boilers with manual and automatic blowdown valves.

3.5 BOILER START-UP (FROM COLD)

Guides on safely raising the boiler temperature to avoid thermal shock.

3.5.1 BOILER START-UP FOLLOWING SHORT TERM SHUT-DOWN

Instructions for restarting the boiler after a short shutdown period.

3.6 BOILER SHUT-DOWN

Procedures for safely shutting down the boiler for various durations.

SECTION 4 - MAINTENANCE

4.4 WATER LEVEL AND LOW WATER SAFETY CONTROL PROCEDURES

Procedures to ensure the correct functioning of water level controls and safety systems.

4.4.1 FEEDWATER PUMP TEST

Procedures to ensure the correct functioning of water level controls and safety systems.

4.4.2 1 ST LOW WATER LEVEL CHECK

Steps to verify the 1st low water level indicator and burner cut-out function.

4.4.3 2 ND LOW WATER LEVEL CHECK

Procedure to test the 2nd low water alarm and burner shut-off sequence.

4.5 BLOWDOWN PROCEDURES

Methods for maintaining boiler water quality by removing sludge and dissolved solids.

4.11 SCHEDULE OF OPERATOR TESTS AND CHECKS

A schedule of tests and checks for boiler operators.

4.11.1 DAILY

Daily checks to ensure safe operation and effective water treatment.

4.11.5 ANNUALLY

Annual inspections and re-certification requirements as per regulations.

4.12 TROUBLESHOOTING

Guidance for diagnosing and resolving common boiler and pump issues.

4.12.1 TROUBLESHOOTING BOILER

Lists common boiler problems, their causes, and remedies.

4.12.2 TROUBLESHOOTING FEEDWATER PUMP

Addresses issues related to the feedwater pump's operation and potential faults.