bintec User’s Guide System
Submenu External System Logging
The settings for saving syslog messages externally are made in S
YSTEM
EXTERNAL SYSTEM LOGGING ADD/EDIT.
The menu consists of the following fields:
Field Description
Log Host ➤➤IP address of the host to which syslog
messages are passed.
Level Priority of the syslog messages to be sent to
LOG HOST. The possible values correspond to
those in
“Message Level for the Syslog Table”
on page 5.
Only syslog messages with the same or higher
priority than indicated are passed to the
LOG
H
OST, i.e. all the messages created are passed
to the
LOG HOST in syslog LEVEL Debug.
Facility Syslog facility at LOG HOST. Only required if the
LOG HOST is a Unix computer.
Possible values: local0 - 7 (default value
local0).
Type Message type. Possible values:
all: All messages (default value)
system: Syslog messages except
➤➤ accounting messages.
accounting: Accounting messages
Timestamp Format of the system time of the R Series gate-
way in the syslog. Possible values:
all: System time with date
time: System time without date
none: No system time shown (default value)