System bintec User’s Guide
19
Submenu Schedule & Monitor
4
Standard actions are the time or data volume dependent activation resp. deac-
tivation of interfaces.
The event scheduler is configured in the SYSTEM ➜ SCHEDULE & MONITOR ➜
E
VENT SCHEDULER (TIME & SNMP) menu:
Activate (enabled) or deactivate (disabled) the scheduler in the EVENT
SCHEDULER field; the default setting is deactivated. When the EVENT SCHEDULER
is activated, the schedule interval is set to 300 seconds as default.
Configure the events that are to initiate a certain action at the gateway in the
SCHEDULE EVENTS menu and the actions to be executed in the SCHEDULE
COMMANDS menu. The triggers (events) can be linked to event chains, so that
complex conditions for initiating an action can also be created.
To be able to use the Event Scheduler function, the date on the gateway must
be at least January 1, 2000.
4.2.1 Configuration of triggers (Events)
The SYSTEM ➜ SCHEDULE & MONITOR ➜ EVENT SCHEDULER (TIME & SNMP) ➜
SCHEDULE EVENTS menu displays a list of all already configured events.
New events are added with ADD, existing entries are modified with EDIT.
Attention!
The configuration of actions that are not available as defaults requires ex-
tensive knowledge of the method of operation of bintec gateways. An in-
correct configuration can cause considerable disturbances in operation.
If applicable, save the original configuration e.g. on your PC.
R232bw Setup Tool Funkwerk Enterprise Communications GmbH
[SYSTEM][SCHEDULED]: Event Schedule MyGateway
Event Scheduler disabled
Schedule Events >
Schedule Commands >
SAVE CANCEL