Page #16 background imageLoading...
Page #16 background image
4
14
bintec User’s Guide System
Submenu Schedule & Monitor
WHAT TO MONITOR: hosts
If hosts has been selected, the KEEPALIVE MONITORINGADD/EDIT menu con-
sists of the following fields:
R232bw Setup Tool Funkwerk Enterprise Communications GmbH
[SYSTEM][KEEPALIVE MONITORING][ADD]: Host Monitoring MyGateway
Group 0
IPAddress
Interval 300
Trials
Source IP
DownAction down
FirstIfIndex 10001
Range 4999
SAVE CANCEL
Field Description
Group Defines a group of hosts, whose reachability is
to be monitored by the gateway. Each host to
be monitored is assigned to a group. A total of
256 groups can be created.
Possible values: 0 (default value) ... 255.
IP Address Defines a host that is to be monitored by the
gateway.
Interval Defines the time interval in seconds to be used
for checking the reachability of hosts. Possible
values:
1 ... 65536 (default value: 300 s).
The smallest INTERVAL of the group members is
used within a group.
Trials Defines the number of pings, that are sent to
check the availability of hosts.
Possible values: 1 ... 65536 (default value: 3).

Other manuals for Funkwerk bintec R230a

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Funkwerk bintec R230a and is the answer not in the manual?

Funkwerk bintec R230a Specifications

General IconGeneral
BrandFunkwerk
Modelbintec R230a
CategoryGateway
LanguageEnglish

Related product manuals