3. ADJUSTMENTS
3-18
[DS-8520 TEST (3/3)]: page 3
3.5.4 RD-502 TEST
Check the connection between DS-85 and the optional Dimmer RD-502.
[MAC ADDRESS] MAC address of transceiver unit [00:00:00:00:00:00] to
[FF:FF:FF:FF:FF:FF]
[DIPSW] Status DIP switch of transceiver unit S2: [0000] to [1111]
S3: [0000] to [1111]
S5: [0000] to [1111]
[TOTAL DIST] Total distance [0.00] to [999999.99]
X key Go to page 3 of the [DS-8520 TEST].
MENU/ESC key Go back to [TEST] sub menu.
Item Meaning Range
[XDCR TEMPERATURE] Temperature of Transducer [-99.9] to [999.9]
([---.-]: circuit error, or no
connection to transducer)
[TRX TEMPERATURE] Temperature of TRX board
on Transducer
[-99.9] to [999.9]
[PWR TEMP] Temperature of PWR board
for transceiver unit
[-99.9] to [999.9]
[B VOLT] B voltage of transceiver unit [0.0] to [99.9]
[5 VOLT] Voltage of 5 V for transceiv-
er unit
[0.0] to [99.9]
[12 VOLT] Voltage of 12 V for trans-
ceiver unit
[0.0] to [99.9]
[24 VOLT] Voltage of 24 V for trans-
ceiver unit
[0.0] to [99.9]
[FAN RPM] Revolution of FAN [0] to [999999]
[NOISE LEVEL (FORE/
AFT)]
Noise level of FORE/AFT
transducer
[-20] to [120.0]
[SPEED (FORE/AFT)] Measured ship’s speed
(FORE/AFT)
[-99.99] to [99.99]
MENU/ESC key Go back to [TEST] sub menu.
Item Meaning Range
- - - . -
32 . 8ºC
25 . 5V
5 . 0V
12 . 1VA / 11. 9VD
8.3 /11 . 5 dBuV
25 .6V
4803rpm
32
. 14/
32 . 22kn