4. AIS OPERATION
4-16
4.11 ROT Setting
You may set the lower limit of the ROT (Rate Of Turn) at which the heading line
on target symbols will point in direction of turning of the vessel.
1. Left-click the MENU box to open the menu.
2. Select 4 [TT/AIS] to open the TT/AIS menu.
[TT
.
AIS SYMBOL]
1BACK
2TT
.
AIS SYMBOL COLOR
RED*/GRN/BLU/YEL*/
CYA/MAG/WHT
3 AIS ROT TAG LIMIT
000.0
˚
/MIN
4 TT PAST POSN POINTS
5/10
5 AIS PAST POSN POINTS
5/10
6 AIS SCALED SYMBOL
OFF/ON
* Not available on IMO type
AIS SYMBOL menu
3. Select 3 AIS ROT TAG LIMIT.
4. Use the numeral keys or the scrollwheel to enter ROT (setting range: 0.1 to
720.0 (°/min)).
5. Push the right button three times to close the menu.
Ship turning
to starboard
ROT display