FURUNO
FAR-21x7/28x7(-BB) SERIES
SP - 3 E3519S01T-M
190508
MU-201CR 24 VDC:2.3 A or 100-230 VAC: 0.7 A max., 1 phase, 50/60 Hz
MU-231CR 24 VDC:3.2 A or 100-230 VAC: 0.9 A max., 1 phase, 50/60 Hz
MU-170C 12-24VDC: 6.0-3.0 A
5.2 Processor unit 24VDC or 100-115/220-230 VAC, 1 phase, 50/60 Hz
FAR-2117(-BB)/2817 24VDC: 7.6A (8.5A) or
100-115 VAC: 2.6A (3.0A), 220-230 VAC: 1.6A (1.7A)
FAR-2127(-BB)/2827 24 VDC: 8.8A (9.7A) or
100-115 VAC: 3.0A (3.4A), 220-230 VAC: 1.8A (1.9A)
( ): Value for 42 rpm antenna unit
FAR-2827W 100-115 VAC: 3.2A, 220-230 VAC: 1.6A
FAR- 2137S/2837S/2837SW 100-115 VAC: 3.0A, 220-230 VAC: 1.5A
5.3 Antenna unit S-band: 200/220/380/440 VAC, 3 phase, 50/60 Hz
Model Antenna voltage input (100 kn)
200VAC,3φ,50Hz
220VAC,3φ,60Hz
380VAC,3φ,50Hz,
440VAC,3φ,60Hz
High speed craft
220VAC,
3φ, 60Hz
440VAC,
3φ, 60Hz
FAR-2137S/2837S 3.0 A 1.5 A 3.5 A 1.7 A
FAR-2837SW 3.0 A 1.5 A - -
5.4 Console 115/230 VAC, 1 phase, 50/60 Hz
5.5
Transformer (option)
For single phase: RU-1803:
440 VAC, 1 phase, 50/60 Hz
For triple phase: RU-5693: 110 VAC, 3 phase, 60 Hz
RU-6522: 220 VAC, 3 phase, 50 Hz
RU-5466-1: 440 VAC, 3 phase, 50 Hz
6 ENVIRONMENTAL CONDITIONS
6.1 Ambient temperature
Antenna unit -25°C to +55°C (storage +70°C)
Others -15°C to +55°C
6.2 Relative humidity 95% or less at +40°C
6.3 Degree of protection
Antenna unit IPX6
Processor/ power supply/ transceiver/ control unit IPX0
Monitor unit MU-201CR/231CR: IPX0,
MU-190/231: IP22,
MU-170C: IP56 (panel), IP20 (chassis)
6.4 Vibration IEC60945 Ed.4
7 UNIT COLOR
7.1 Antenna unit N9.5 (fixed)
7.2 Processor/ power supply/ transceiver/ control unit
2.5GY5/1.5
7.3 Monitor unit
MU-201CR/231CR N3.0 (panel) , 2.5GY5/1.5 (chassis)
MU-190/231/170C N2.5 (fixed)

Table of Contents