EasyManua.ls Logo

Furuno FE-700 - System Overview; System Configuration

Furuno FE-700
43 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FURUNO
FE-700
E2366S01T
1.1 Transmit fre uency 50 k , 200 k , or 50/200 k alternating transmit
1.2 Output power 600 Wrms
1.3 Beam width 50B-6B 50 k 35 , 200B-8B 200 k 6
1.4 Basic display range
Range
Unit
1 2 3 4 5 6 7 8
Meter 5 10 20 40 100 200 400 800
Feet 15 30 60 120 300 600 1500 2500
Fathom 3 5 10 20 50 100 200 400
Default settings it could be customi ed for use w/o range 3 and 6.
1.4 Accuracy 2.5 on any range
1.5 Minimum range 0.5 m 200 k , 2.0 m 50 k
1.6 Draft 0 to 30 m in 0.1 m steps, default 0 m
1.7 Pulse repetition rate PRR
Depth m P/L ms PRR pulse/min
5, 10, 20 0.25 750
40 0.38 375
100 1.00 150
200 2.00 75
400,800 3.60 42
2.1 Graphical display 6.5-inch color TFT LCD, 320 234 pi els
2.2 Echo colors 8 colors or 8 level monochrome
2.3 Display area 133 97 mm
2.4 Display mode
NAV Basic echo presentation with the depth below transducer or keel
DBS Echo presentation with the depth below sea surface
ISTR istorical Echo presentation with the depth
LOGBOO Echo presentation with the pop-up table showing
Time, Depth and L/L data memori ed at preset interval
OS DATA Echo presentation with the pop-up table of present
navigational data L/L , course , speed , time, depth
ELP Echo presentation with the help menu and note
MENU Echo presentation with the user menu
2.5 Picture advance speed
Slow mode 15 minutes or more
Fast mode Picture advance range
Range m 5 10 20 40 100 200 400 800
Interval min. 1.8 8 20 30
2.6 User setting Gain, Range, Alarm, Draft, Brilliance, Dimmer, Color, Auto
2.7 Auto set mode Gain, range and clutter will be automatically ad usted.
2.8 Alarm Shallow water default 20 m , Bottom lost, Power drop
2.9 Logbook display Depth, Internal clock, L/L