5. CALLING, RECEIVING
5-37
3. Press the [CANCEL] key to silence the alarm, and the display changes as below.
MAR-23-2002-23:59:09
POSITION ACKNOWLEDGE
TO SHIP :
987654321
ROUTINE
POS :
35
°
00N 135
°
00E AT 23:59
**
Xmitted message
**
GO TO ALL VIEW
4. Press the [CANCEL] key to return to the DSC standby screen.
Manual reply
1. When a position request call is received and the status of the [5/ ACK/SQ] key is
MANUAL ACK, the audio alarm sounds and the display changes as below.
Position request
call received.
FROM SHIP: 123456789
ROUTINE
STOP ALARM
2. Press the [CANCEL] key to silence the alarm. The display changes as below.
ECC: OK
POSITION REQUEST
FROM SHIP :
123456789
ROUTINE
*
Received message
*
ANSWER
34
ALL VIEW
MAR-23-2002-23:00:01
3. Rotate the [ENTER] knob to choose ANSWER and then push the [ENTER] knob. Your
display should now look something like the one below.
CALL TYPE: POSITION
ACKNOWLEDGE
POSITION :
35 00N 135 00E
UTC TIME :
23:01
DSC FREQ :
2177.0 KHZ
GO TO ALL VIEW
**
Compose message
**